Collect tips automatically after dressing
Perlengkapan Tambahan: Perlengkapan pendukung tip dresser dan tip changer: memeriksa permukaan cap tip OK/NG dengan sensor (FIXA2) atau kamera (TMN-01), mengumpulkan serpihan hasil rapikan (CVC5), dan meniup serpihan dari holder (CD-AB).
-
| Model | CVC5-** (Open Type Vacuum Unit) |
| Corresponding dressers | CDK-R, CDK-SG, CDK-BAYO, CDK-DUAL, CD-SVR |
| Recommended solenoid valve | VP342-5G1-02A (SMC) |
| Air blower | Standard equipment |
| Holder cover | Standard equipment |
| Timing chart – Gun pressure | 1sec |
| Timing chart – CVC / Air blower (SOL) | ON 1~3sec before gun pressure, OFF 3~4sec after gun pressure |
| Note | CDK-R and stand are sold separately |