Product Description
As Vapour Flux is supplied from supplementary tank as much as it is used. Level of Vapour Flux is kept fixed level always. Level is kept fixed by controlling 2 pcs. of valves which are attached between supplementary tank and Vapour Tank. Valve control is operated with built-in control unit. One cycle operation of valve can supply about 100cc of Vapour Flux into Vapour Tank. If the temperature is less likely to vaporize flux low, it is also possible to use put a hot water around the tank. (High water type) ※ The photo will be high water type. ## Special Features * Since stable Vapour Flux evaporation can be obtained with Vapour Flux fixed level function, heating conditions are stable and good brazing can be performed. * Since sensor is not used, there is no adjustment place. * As quantity of Vapour Flux can be kept a little in Vapour Tank, staying Vapour Flux is decreased in Vapour Tank. Therefore, aging of Vapour Flux can be prevented and stable evaporation can be obtained. * Between V